Studi Perancangan Instalasi Penerangan dan Pengkondisi Suhu Ruangan Pada Gedung Bertingkat Las Mesin

  • Vicky Prasetia Politeknik Negeri Cilacap
  • Erna Alimudin (Scopus ID: 57142511900). Politeknik Negeri Cilacap https://orcid.org/0000-0002-3788-0676
  • Purwiyanto Purwiyanto Politeknik Negeri Cilacap
  • Muhamad Yusuf Politeknik Negeri Cilacap
  • Mohammad Nurhilal Politeknik Negeri Cilacap
Abstract views: 251 , PDF downloads: 383
Keywords: building lightning, air conditioner, electrical planning

Abstract

Lighting is one of the most important requirements of a building. This is because inadequate lighting of a space can affect the health and comfort of activities in that space. In addition to less important lighting, room temperature adjustments, room temperature adjustments have a significant impact on comfort during activities in the room. This magazine describes the lighting and room temperature control design of the CilacapState Polytechnic Welder Shop. The method used in this study is a quantitative method. This method calculates the required lighting and room temperature control and compares it with the standards. 2 rooms increase the number of light points and 3 rooms change the type of lamp with a higher lumen. There are 8 rooms that are recommended to use air conditioners with SNI 91714189. According to the SNI, the number of air conditioners and the capacity of air conditioners adjusts to the size of the room.

 

References

Badan Standardisasi Nasional, “Prosedur Audit Energi,” p. 6196, 2011.

T. Penerbangan, S. Tinggi, and P. Indonesia, “SNI (Standar Nasional Indonesia),” no. 1, pp. 61–70.

SNI 6197, “SNI 6197: 2011 Konservasi Energi pada Sistem Pencahayaan,” Standar Nas. Indones., pp. 1–38, 2011.

SNI, “Tata cara perancangan sistem pencahayaan buatan pada bangunan gedung,” Sni 03-2396-1991, p. 2396, 1991.

“British thermal unit,” Encycl. Dict. Polym., pp. 129–129, 2007.

P. A. Dermawan, “Studi Evaluasi Perencanaan Instalasi Penerangan Hotel Neo By Aston Pontianak,” J. Tek. Elektro Univ. Tanjungpura, vol. 2, no. 1, 2017.

T. Hidayat, “Analisis Audit Energi Listrik Pada Sistem Pengkondisian Udara ( Studi Kasus di Ruang Kelas Fakultas Ekonomi Universitas Tanjungpura ),” Elkha, vol. 7, no. 1, pp. 18–24, 2015.

M. A. Hamdy, N. Jamala, R. Rahim, R. Mulyadi, and A. Kusno, “PERKULIAHAN Studi Kasus : Ruang Perkuliahan Universitas Bosowa Pendahuluan Pencahayaan merupakan bagian penting dari dalam menunjang produktivitas kerja manusia . Pencahayaan buruk dapat dapat menimbulkan gangguan kesehatan , khususnya gangguan mata . Des,” Atrium, vol. 5, no. 1, pp. 1–11, 2019.

L. M. Parera, H. K. Tupan, and V. Puturuhu, “Analisis Pengaruh Intensitas Penerangan Pada Laboratorium Dan Bengkel Jurusan Teknik Elektro,” J. Simetrik, vol. 8, no. 1, pp. 60–67, 2018.

S. A. Suwarlan, “Evaluasi Kenyamanan Visual Pada Pencahayaan Ruang Kelas Melalui Simulasi Komputansi Arsitektur Digital,” J. Arsit. ARCADE, vol. 5, no. 2, p. 165, 2021.

V. Letschert, S. Price, W. Y. Park, N. Karali, N. Abhyankar, and ..., “Accelerating the Transition to More Energy Efficient Air Conditioners in Indonesia,” 2020.

D. Setyawan and M. Subekti, “Desain Intensitas Penerangan dengan Tipe Jenis Lampu untuk Kegitan Praktikum di Laboratorium Mesin Listrik dan Pengukuran,” J. Pengelolaan Lab. Pendidik., vol. 3, no. 2, pp. 47–55, 2021.

M. Penggunaan et al., “Analisis Pengurangan Emisi CO 2 Melalui Ketersediaan Ruang Terbuka Hijau di Gedung Perkantoran Pemerintah Kota Surabaya,” vol. 2, no. 3, pp. 214–217, 2013.

Y. R. Lesdiyanto, “Perancangan Sistem Pengkondisian Udara Untuk Gedung Perkantoran,” Universsitas Sanata Dharma, pp. 1–157, 2008.

S. Kurniasih and O. Saputra, “Evaluasi Tingkat Pencahayaan Ruang Baca Pada Perpustakaan Universitas Budi Luhur, Jakarta,” J. Arsit. ARCADE, vol. 3, no. 1, p. 73, 2019.

PlumX Metrics

Published
2023-07-31